DC/AC
Pure Sine Wave Inverter ( S150 ) |
|
Pure
sine wave output (THD< 4% ).
Input
& output fully isolation design
Capable
of driving highly reactive & capacitive
loads at start moment.
Tri-Color
indicators display input voltage, output
load level and failure status.
Loading
controlled cooling fan
Advanced
microprocessor
SC
/ OV / UV / OT / OL protections.
|
 |
<Datasheet
Download>
|
|
Specification |
Model No. |
Item |
S150-112 |
S150-124 |
S150-212 |
S150-224 |
Continuous Output power |
150W
|
Surge Rating |
200W |
Input Voltage |
12V |
24V |
12V |
24V |
Output Voltage |
110VAC ¡Ó5% |
230VAC ¡Ó5% |
Frequency
(Switch Selectable)
|
50/60Hz +/- 0.3% |
Efficiency
(Peak
Load)
|
91% |
92% |
90% |
93% |
Efficiency
(Max.
/ Avg.)
|
86% |
87% |
85% |
88% |
Efficiency
(Full
Load)
|
72% |
79% |
72% |
80% |
No
Load Current Draw |
0.18A |
0.15A |
0.22A |
0.16A |
Output Waveform |
Pure Sine Wave ( THD < 4% ) |
Power
Factor Allowed |
cos£c-90¢X ~ cos£c+90¢X |
Protection |
Overload,
Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature. |
RRemote
Control |
Yes, On/Off controlled by external switch |
Safety |
UL458 Pending |
EN60950 Pending |
EMC |
FCC Class B |
EN50081-1:1992
EN50082-1:1992
EN55022B:1994
EN61000-4-2:1995
EN61000-4-3:1996
ENV50204:1995
Pending
|
e-Mark
e13-022025
|
Operating Temperature Range |
0-40¢J |
Storage Temperature Range |
-30¢J to 70¢J |
Cooling |
Loading controlled cooling fan |
Dimensions |
200
x 132 x 72 mm / 7.87 x 5.20 x 2.83 inch |
Weight |
2.7 kg / 5.4 Lb |
*110V
mode design meets UL 458 & FCC Class B.
**230V
model design meets CE & ¡§e ¡§ Mark.
(Currently, all applied projects are pending) |
|
|
¡
|
DC/AC
Pure Sine Wave Inverter ( S300 ) |
|
Pure
sine wave output (THD< 4% ).
Input
& output fully isolation design
Capable
of driving highly reactive & capacitive
loads at start moment.
Tri-Color
indicators display input voltage, output
load level and failure status.
Loading
controlled cooling fan
Advanced
microprocessor
SC
/ OV / UV / OT / OL protections.
|
|
<Datasheet
Download>
|
|
Specification |
Model No. |
Item |
S300-112 |
S300-124 |
S300-212 |
S300-224 |
Continuous Output power |
300W
|
Surge Rating |
400W |
Input Voltage |
12V |
24V |
12V |
24V |
Output Voltage |
110VAC ¡Ó5% |
230VAC ¡Ó5% |
Frequency
(Switch Selectable)
|
50/60Hz +/- 0.3% |
Efficiency
(Peak
Load)
|
92% |
93% |
91% |
94% |
Efficiency
(Max.
/ Avg.)
|
87% |
88% |
86% |
89% |
Efficiency
(Full
Load)
|
72% |
78% |
72% |
80% |
No
Load Current Draw |
0.26A |
0.23A |
0.23A |
0.15A |
Output Waveform |
Pure Sine Wave ( THD < 4% ) |
Power
Factor Allowed |
cos£c-90¢X ~ cos£c+90¢X |
Protection |
Overload,
Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature. |
RRemote
Control |
Yes, On/Off controlled by external switch |
Safety |
UL458 Pending |
EN60950 Pending |
EMC |
FCC Class B |
EN50081-1:1992
EN50082-1:1992
EN55022B:1994
EN61000-4-2:1995
EN61000-4-3:1996
ENV50204:1995
Pending
|
e-Mark
e13-022078
|
Operating Temperature Range |
0-40¢J |
Storage Temperature Range |
-30¢J to 70¢J |
Cooling |
Loading controlled cooling fan |
Dimensions |
237
x 155 x 72 mm /9.36 x 6.10 x 2.83 inch |
Weight |
3.5 kg / 7.7 Lb |
*110V
mode design meets UL 458 & FCC Class B.
**230V
model design meets CE & ¡§e ¡§ Mark.
(Currently, all applied projects are pending) |
|
¡@
|
DC/AC
Pure Sine Wave Inverter ( S600 ) |
|
Pure
sine wave output (THD< 3% ).
Output
frequency : 50/60Hz switch selectable
Input
& output fully isolation design
High
efficiency 88~94%
Capable
of driving highly reactive & capacitive
loads at start moment.
Tri-Color
indicators display input voltage, output
load level and failure status.
Loading
controlled cooling fan
Advanced
microprocessor
SC / OV / UV / OT / OL protections.
|
<Datasheet
Download>
|
|
Specification |
Model No. |
Item |
S600-112 |
S600-124 |
S600-148 |
S600-212 |
S600-224 |
S600-248 |
Continuous Output power |
600W
|
Maximum Output Power ( 3Min ) |
680W |
Surge Rating |
800W |
Input Voltage |
12V |
24V |
48V |
12V |
24V |
48V |
Output Voltage |
100/110/120VAC ¡Ó3% |
220/230/240VAC ¡Ó3% |
Frequency (Switch Selectable) |
50/60Hz +/- 0.05% |
Efficiency
(Full
load) |
87% |
90% |
92% |
90% |
93% |
94% |
No Load Current Draw |
0.87A |
0.43A |
0.23A |
0.83A |
0.43A |
0.22A |
Output Waveform |
Pure Sine Wave < 3% THD |
Output Voltage Regulation |
100/110/120Vrms-10%/+4% |
220/230/240Vrms-10%/+4% |
Input Voltage Regulation |
10.5-15 |
21.0-30 |
42.0-60 |
10.5-15 |
21.0-30 |
42.0-60 |
Input Level Indicator |
Red / Orange / Green LED |
Load Level Indicator |
Failure Indicator |
Red LED |
Protection |
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature
|
Remote
Control |
Yes, On/Off controlled by external switch
|
Protection |
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature
|
Safety |
UL458 |
EN60950 |
EMC |
FCC Class B |
EN50081-1:1992
EN50082-1:1992
EN55022B:1994
EN61000-4-2:1995
EN61000-4-3:1996
ENV50204:1995
|
e-Mark
e13-020866
|
Operating Temperature Range |
0-40¢J |
Storage Temperature Range |
-30¢J to 70¢J |
Cooling |
Loading controlled cooling fan |
Dimensions |
295 (L) x 180 (W) x 72 (H) mm
/ 11.61 (L) x 7.09 (W) x 2.83 (H) Inch |
Weight |
2.7kg / 5.4Lb |
|
|
DC/AC
Pure Sine Wave Inverter ( S1000 ) |
 |
Pure
sine wave output (THD< 3% ).
Output
frequency : 50/60Hz switch selectable
Input
& output fully isolation design
High
efficiency 89~95%
Capable
of driving highly reactive & capacitive
loads at start moment.
Tri-Color
indicators display input voltage, output
load level and failure status.
Loading
controlled cooling fan
Advanced
microprocessor
SC
/ OV / UV / OT / OL protections.
|
|
<Datasheet
Download>
|
|
Specification |
Model
No. |
Item |
S1000-112 |
S1000-124 |
S1000-148 |
S1000-212 |
S1000-224 |
S1000-248 |
Continuous
Output power |
1000W
|
Maximum
Output Power (3Min) |
1150W
|
Surge
Rating |
1300W
|
Input
Voltage |
12V |
24V |
48V |
12V |
24V |
48V |
Output
Voltage |
100/110/120VAC
¡Ó3% |
220/230/240VAC
¡Ó3% |
Frequency(Switch Selectable) |
50/60Hz
+/- 0.05% |
Efficiency
(Full
load) |
89% |
92% |
93% |
91% |
94% |
95% |
No
Load Current Draw |
1.2A |
0.6A |
0.3A |
1.2A |
0.6A |
0.28A |
Output
Waveform |
Pure
Sine Wave ( THD < 3% ) |
Output
Voltage Regulation |
100/110/120Vrms-10%/+4% |
220/230/240Vrms-10%/+4% |
Input
Voltage Regulation |
10.5-15.0 |
21.0-30.0 |
42.0-62.0 |
10.5-15.0 |
21.0-30.0 |
42.0-62.0 |
Input Level Indicator |
Red
/ Orange / Green LED
¡@
|
Load Level Indicator |
Failure
Indicator |
Red
LED
|
Protection |
Overload,
Short Circuit, Reverse Polarity (Fuse),
Over
/ Under Input Voltage, Over Temperature
|
Remote
Control Unit |
CR-6
( Optional ) |
Safety |
UL458
Pending |
EN60950
Pending |
EMC |
FCC
Class B Pending |
EN50081-1:1992
Pending
EN50082-1:1992
Pending
EN55022B:1994
Pending
EN61000-4-2:1995
Pending
EN61000-4-3:1996
Pending
ENV50204:1995
Pending
|
Operating
Temperature Range |
0-40¢J |
Storage
Temperature Range |
-30¢J
to 70¢J |
Cooling |
Thermostatically
controlled cooling fan |
Dimensions |
383
(L) x 182 (W) x 89 (H) mm / 15.08 (L) x 7.17 (W)
x 3.5 (H) Inch |
Weight |
4.0kg
/ 8.8 Lbs. |
|
|
DC/AC
Pure Sine Wave Inverter ( S1500 ) |
|
Pure
sine wave output. (< 3% THD)
"Low
power Power Saving Mode" to
conserve energy.
RS¡V232C
interface / remote controls port.
Built-in
voltage and watt meters.
Thermostatically
controlled cooling fan.
Advanced
microprocessor .
SC
/ OV / UV / OT / OL Protections.
Output
Voltage / Frequency Switch Selectable.
|
<Datasheet
Download>
|
|
Specification |
Model
No. |
Item |
S1500-112 |
S1500-124 |
S1500-148 |
S1500-212 |
S1500-224 |
S1500-248 |
Continuous
Output power |
1500W
|
Surge
Rating |
2000W
|
Input
Voltage |
12V |
24V |
48V |
12V |
24V |
48V |
Output
Voltage |
100/110/120VAC
¡Ó3% |
220/230/240VAC
¡Ó3% |
Frequency(Switch Selectable) |
50/60Hz
+/- 0.05% |
Peak
Output Current |
25A |
11A |
Efficiency(Full
load) |
85% |
87% |
88% |
86% |
89% |
90% |
No
Load Current Draw |
<1.5W
Saving Mode |
Output
Waveform |
Sine
Wave < 3% THD |
Output
Voltage Regulation |
100/110/120Vrms-10%/+4% |
220/230/240Vrms-10%/+4% |
Input
Voltage Regulation |
10.0-16.0 |
20.0-32.0 |
42.0-62.0 |
10.0-16.0 |
20.0-32.0 |
42.0-62.0 |
Protection |
Overload,
Short Circuit, Reverse Polarity (Fuse),
Over
/ Under Input Voltage, Over Temperature
|
Power
Saving Recovery Time |
5
Second |
Interface
Control Port |
RS-232C
With Baud Rate 1200, 2400, 4800 (Switch Selectable) |
Remote
Control Unit |
CR-5
( Optional ) |
Safety |
UL458 |
EN60950 |
EMC |
FCC
Class B |
EN50081-1:1992
EN50082-1:1992
EN55022B:1994
EN61000-4-2:1995
EN61000-4-3:1996
ENV50204:1995
|
e-Mark
e13-020932
|
Operating
Temperature Range |
0-40¢J |
Storage
Temperature Range |
-30¢J
to 70¢J |
Cooling |
Thermostatically
controlled cooling fan |
Dimensions |
390
(L) x 275 (W) x 105 (H) mm / 15.4 (L) x 10.8 (W)
x 4.1 (H) Inch |
Weight |
7.0kg
/ 15.5Lb. |
|
|
© The copyright by
the COTEK ELECTRONIC IND. CO., LTD. All Rights Reserved.
Unauthorized copying and reproduction are prohibited.
Web Designed by : SIOW DESIGN
¡
|
|
|